| MIL811
|
Portable Vibration Meter (Accelerometer)
Part Number M81101
The Mechanalysis model MIL811 plays a dual role in
machinery maintenance: - It is used for periodic vibration
checks for unbalance, misalignment, looseness, etc.
With an industry standard high frequency detection
circuit, it pinpoints incipient bearing and gear deterioration.
Its solid-state circuitry provides wide dynamic range
and long battery life. From precision bearing inspection
to plant-wide maintenance, the MIL811 has the sensitivity
for measuring fractions of a micrometer to 3000 micrometers
with 8 easy to read overlapping ranges.
The MIL811 also includes the widely acclaimed IRD
Spike energy circuit. The broadband measurement of
Spike Energy (units of gSETM) has proved
to have the advantage of simplicity and earlier warning
of bearing and gear defects.
By detecting and measuring “bursts” of
spike energy at ultrasonic frequencies, defects such
as micro spalls and cracks and lack of lubrication
can be quickly identified.
|
| |
|
|
Standard
Accessories |
Qty |
Part Number
|
| Accelerometer
ICP |
1 |
M19697 |
| Cable for Accelerometer
ICP 1.21m (4 ft) |
2 |
M27917 |
| Straight Probe |
1 |
M11030 |
| Battery Set,
2 Nos. of 9V, 100mAH Dry Cells |
2 |
M12359 |
| Carrying/Accessory
Case |
1 |
M25345 |
| Manual Operating
|
1 |
M21072 |
|
Optional
Accessories |
|
Part Number
|
| Vibration Velocity
Sensor model MIL544 |
|
M45260 |
| Cable for Model
MIL544 Sensor 1.21m (4 ft) |
|
M20432 |
| Cable for Model
MIL544 Sensor 7.62m (25 ft) |
|
M21045 |
| Cable for Accelerometer
ICP 7.62m (25 ft) |
|
M21044 |
| Magnetic Sensor
Holder for IRD544 MIL Spec. |
|
M43320 |
| Magnetic Sensor
Holder for Accelerometer ICP |
|
M24746 |
| Magnetic Shield
for model MIL544 Sensor |
|
M10449 |
| Calibrator |
|
M21073 |
| Scope/Analyser
AC output |
|
M58570 |
| Manual Training
- Vibration Technology 1 |
|
M51001 |
|
| |
Specifications |
|
| |
| Frequency
– with Model 970 Accelerometer |
| |
| Displacement : |
350 to 60,000 CPM |
( 5.8 Hz to 1,000Hz) |
| Displacement : |
1400 to 300,000 CPM |
(23.3 Hz to 5,000 Hz) |
| Velocity : |
350 to 600,000 CPM |
( 5.8 Hz to 1,000 Hz) |
| Acceleration : |
350 to 600,000 CPM |
( 5.8 Hz to 1,000 Hz) |
| Bearing/Gear : |
Up to ultrasonic frequencies |
|
| RMS : |
VRMS – ISO2373 & BS4675 |
|
|
| |
|
| Amplitude |
|
| Acceleration Range : |
0 to 100 g Pk in 8 overlapping ranges |
| Bearing/Gear Check Range : |
0 to 100 gSETM in 8 overlapping ranges |
| Spike Energy : |
Special circuit designed to detect gSETM |
| Displacement Range : |
0 to 3,000 microns Pk to Pk in 8 overlapping ranges |
| Velocity Range : |
0 to 3,000 mm/sec Pk in 8 overlapping ranges: |
|
| |
|
|
| Frequency
– with MIL544 velocity sensor |
| |
| Displacement (350 CPM) : |
600 to 60,000 CPM |
( 5.8 Hz to 1,000 Hz ) |
| Displacement (1400 CPM) : |
1400 to 60,000 CPM |
(23.3 Hz to 5,000 Hz) |
| Velocity: |
600 to 60,000 CPM |
( 10 Hz to 5,000 Hz) |
|
| |
|
|
| Amplitude |
|
| Displacement Range : |
0 to 3,000 microns Pk to Pk in 8 overlapping ranges |
| Velocity Range : |
0 to 3,000 mm/sec Pk in 8 overlapping ranges: |
|
| |
|
|
| Input
/ Output |
|
| Inputs: |
Accelerometer ICP |
| |
MIL544 Velocity Sensor |
| |
Quick-connect receptacle |
| Outputs: |
Analog amplitude meter, microns, mm/sec,
g, gSETM |
| |
Scope/Tape Recorder/Analyser AC output receptacle |
|
| |
|
|
| Power
Requirements |
|
| Internal Batteries: |
Battery Set, 2 Nos. 9V, 100 mAH Dry Cells |
| Battery Test: |
Battery condition check indicated on meter |
|
| Environmental |
|
| Operating temp: |
-1°C to 65°C |
| Storage temp: |
-20°C to 65°C |
|
|
|
| Packaging
|
|
| Case: |
Aluminium with dust and splash proof seal |
| Battery compartment: |
Easy access for quick change of batteries |
| Carrying case: |
Holds instrument and standard accessories |
|
| Weight
& Dimensions |
|
| Instrument: |
1.05 Kg |
| Dimensions: |
210mm (L)× 116mm (W) × 78mm (D) |
| Carrying Case : |
2.25 Kg ( inc. meter, standard accessories ) |
|
| |
|
| |
|
| |
|
|
TM Spike Energy
and gSE is a trademark of IRD Mechanalysis Inc. |
| |
|
| |
|
| |
|
Mechanalysis
(India) Ltd. strives to continue to improve the above
specification and retains the right to change them without
notice |
|
|
|
|